当前位置: 首页 > 美军标 MIL > MIL-PRF > MIL-PRF-28776D
MIL-PRF-28776D
世界资料网 / 2021-08-02
MIL-PRF-28776D, PERFORMANCE SPECIFICATION, RELAYS, HYBRID, ESTABLISHED RELIABILITY, GENERAL SPECIFICATION FOR (26 SEP 2005) [SUPERSEDING MIL-R28776B]., This specification establishes the general requirements for relays that use a combination of solid state circuit input elements functioning with an electro-mechanical relay that performs the switching functions associated with control system applications (see 6.1). These relays are designed to operate in low and medium power switching circuits with contact ratings up to 1 ampere alternating current (ac) or direct current (dc). The failure rate level is established at a confidence level of 90 percent for qualification and 60 percent for maintenance of qualification based on 100,000 cycles at +125°C under rated load conditions specified herein. Excludes time delay relays. CAUTION: The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay. CAUTION: Pick-up, hold, and dropout voltages are for test purposes only and are not to be used as design criteria. For additional application and caution information, see 6.1.
关键字: MIL-PRF-28
上一篇:MIL-PRF-28800F
下一篇:MIL-PRF-28750/8C

用户评论(共0条评论)

  • 暂时还没有任何用户评论
总计 0 个记录,共 1 页。 第一页 上一页 下一页 最末页
用户名: 匿名用户
E-mail:
评价等级: